The Emergence of OS Native Multipathing Solutions

In today’s Business environment, High Availability is not an option. It is a business necessity and is essential in providing Business Continuity. Data is the lifeblood of a Business. Can you imagine a financial firm loosing connectivity to its Business Critical Database in the middle of the day?

This is where Multipathing or Path failover solutions can address High Availability and Business Continuity because not only do they eliminate single points of failure between the server and the storage but also help in achieving better performance by balancing the load (I/O load or LUN load) across multiple paths.

Most new servers bought today by customers connect into SANs. Furthermore, most of these servers have high availability and redundancy requirements thus are connecting to highly available, redundant fabrics and disk arrays. When any component in the data path fails, failover to the surviving data path occurs non-disruptively and automatically.
So the premise of Multipathing or path failover is to provide redundant server connections to storage and:
  • Provide path failover in the event of a path failure
  • Monitor I/O paths and provide alerts on critical events


Over the years, administrators have recognized this need and so after the purchase of a server, they would also purchase a 3rd party multipathing solution, typically from their storage vendor. Apart from the fact that these 3rd party solutions were not designed as part of Operating System and some did not integrate particularly well, in addition, they did not interoperate well with multipathing solutions from other storage vendors that needed to installed on the same server. In essence, storage vendor specific multipathing solutions solved one problem while creating another one. This problem has lasted for years and was addressed only recently.


Over the past 2-3 years a flurry of OS native multipathing solutions have emerged. Thus, today’s multipathing solution distribution model has changed drastically. Multipathing solutions can be distributed either as:

  • 3rd party software (Symantec/Veritas DMP, PowerPath, HDLM, SDD, RDAC, SANPath etc).
  • Embedded in the Operating System (Solaris MPxIO, AIX MPIO, Windows MPIO, Linux Device Mapper-Multipath, HP-UX PVLinks, VMware ESX Server, Netware via NSS).
  • As an HBA vendor device driver that works with most, if not all, storage arrays (i.e Qlogic’s Linux/Netware failover driver, Windows QLDirect)
  • As an HBA vendor device driver (Emulex MultiPulse) available to OEMs only who in turn incorporate the technology into their own products via calls made to the HBA APIs provided by the HBA vendor.


Increasingly, the trend is toward the deployment of OS native multipathing solutions. In fact, with the exception of one Operating System, a substantial server/storage vendor has all but abandoned support of their traditional Multipathing solution for their newer storage arrays, in favor of the OS native ones.

There are two drivers behind this trend. Cost is one reason customers elect to deploy OS native multipathing solutions. After all, you can’t beat “free”. A secondary, but equally important, driver is to achieve better interoperability among various vendors’ storage devices that happen to provision the same server(s). One driver stack and one set of HBAs talks to everybody.

From a Windows standpoint, it is important to note that Microsoft is strongly encouraging all storage vendors to support its MPIO specification. Network Appliance supports this specification with a Device Specific Module (DSM) for our disk subsystems. It’s equally important to note that Windows MPIO enables the co-existence of multiple storage vendor DSMs within the same server. In fact, the current approach is similar to what Symantec/Veritas has done over the years with the Array Support Library (ASL) that provides vendor disk subsystem attributes and multipathing information to the Symantec/Veritas Device Discovery Layer (DDL) and Dynamic Multipathing (DMP) components.

Early last year Microsoft indicated they were considering the development of a Generic DSM for Fibre Channel (Generic DSM for iSCSI already exists) that will support all storage vendors as long as they (storage vendors) comply with the SCSI Primary Commands revision 3 (SCP-3). Furthermore, Microsoft, at the time, indicated that a Generic DSM would be incorporated into the Windows Vista release.

Network Appliance’s primary multipathing approach is to support all OS native multipathing solutions, as well as, support some popular 3rd party (i.e Symantec/VxDMP) solutions across all supported Operating Systems. Depending on customer demand, certification with disk array vendor specific multipathing solutions is always a possibility, assuming the necessary Customer Support Agreements are in place.


Thursday, August 31, 2006

Linux Native Multipathing (Device Mapper-Multipath)

Over the past couple of years a flurry of OS Native multipathing solutions have become available. As a result we are seeing a trend towards these solutions and away from vendor specific multipathing software.

The latest OS Native multipathing solution is Device Mappper-Multipath (DM-Multipath) available with Red Hat Enterprise Linux 4.0 U2 and SuSE SLES 9.0 PS2.

I had the opportunity to configure it in my lab a couple of days ago and I was pleasantly surprised as to how easy was to configure it. Before I show how it's done, let me talk a little about how it works.

The multipathing layer sits above the protocols (FCP or iSCSI), and determines whether or not the devices discovered on the target, represent separate devices or whether they are just separate paths to the same device. In this case, Device Mapper (DM) is the multipathing layer for Linux.

To determine which SCSI devices/paths correspond to the same LUN, the DM initiates a SCSI Inquiry. The inquiry response, among other things, carries the LUN serial number. Regardless of the number paths a LUN is associated with, the serial number for the LUN will always be the same. This is how multipathing SW determines which and how many paths are associated with each LUN.

Before you get started you want to make a sure the following things are loaded:

  • device-mapper-1.01-1.6 RPM is loaded
  • multipath-tools-0.4.5-0.11
  • Netapp FCP Linux Host Utilities 3.0

Make a copy of the /etc/multipath.conf file. Edit the original file and make sure you only have the following entries uncommented out. If you don't have Netapp the section then add it.


defaults {
user_friendly_names yes
}
#
devnode_blacklist {
devnode "sd[a-b]$"
devnode "^(ramrawloopfdmddm-srscdst)[0-9]*"
devnode "^hd[a-z]"
devnode "^cciss!c[0-9]d[0-9]*"
}


devices {
device {
vendor "NETAPP "
product "LUN"
path_grouping_policy group_by_prio
getuid_callout "/sbin/scsi_id -g -u -s /block/%n"
prio_callout"/opt/netapp/santools/mpath_prio_ontap /dev/n"
features "1 queue_if_no_path"
path_checker readsector0
failback immediate
}
}

The devnode_blacklist includes devices for which you do not want multipathing enabled. So if you have a couple of local SCSI drives (i.e sda and sdb) the first entry in the blacklist will exclude them. Same for IDE drives (hd).


Add the multipath service to the boot sequence by entering the following:

chkconfig --add multipathd
chkconfig multipathd on


Multipathing on Linux is Active/Active with a Round-Robin algorithm.

The path_grouping_policy is group_by_prio. It assigns paths into Path Groups based on path priority values. Each path is given a priority (high value = high priority) based on a callout program written by Netapp Engineering (part of the FCP Linux Host Utilities 3.0).

The priority values for each path in a Path Group are summed and you obtain a group priority value. The paths belonging to the Path Group with the higher priority value are used for I/O.

If a path fails, the value of the failed path is subtracted from the Path Group priority value. If the Path Group priority value is still higher than the values of the other Path Groups, I/O will continue within that Path Group. If not, I/O will switch to the Path Group with highest priority.

Create and map some LUNs to the host. If you are using the latest Qlogic or Emulex drivers, then run the respective utilities they provide to discover the LUN:



  • qla2xxx_lun_rescan all (QLogic)
  • lun_scan_all (Emulex)

To view a list of multipathed devices:

# multipath -d -l

[root@rhel-a ~]# multipath -l

360a9800043346461436f373279574b53
[size=5 GB][features="1 queue_if_no_path"][hwhandler="0"]
\_ round-robin 0 [active] \
\_ 2:0:0:0 sdc 8:32 [active]
\_ 3:0:0:0 sde 8:64 [active]
\_ round-robin 0 [enabled]
\_ 2:0:1:0 sdd 8:48 [active]
\_ 3:0:1:0 sdf 8:80 [active]

The above shows 1 LUN with 4 paths. Done. It's that easy to set up.